Images http://i1.adis.ws/i/pcec/noimagemedium?$PDP-Hero-Image-Desktop$
overview

Single Split System - Wall Mounted Air Conditioner

Details
KS18NKU
Features
  • Wall Mounted Air Conditioner
  • CS-KS18NKU (Indoor Unit)/CU-KS18NKU (Outdoor Unit)
  • Capacity Cooling: 17,500 (4,000-17,500)/Btu

    Features

    Panasonic’s Ductless Split Air Conditioner products offer wide versatility in solving your cooling for a single. The Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit(condenser) via refrigerant lines & inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.

    Microprocessor-Controlled Operation

    Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.

    Wireless Remote Control

    Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.

    Self-Diagnosing Function

    Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)

    Dry Mode

    By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.

    3 Fan Speeds and Automatic Fan Operation

    Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.

    Air Sweep Control

    The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.

    Louver Control

    Louver can be manually set to the desired angle by remote control.

    Night Setback Mode for Cooling and Heating

    Cooling and DRY Mode: With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes. Heating Mode: With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.

    24-hour Clock with ON/OFF Program Timer

    The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.

    1-hour OFF Timer

    When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.

    Automatic Restart Function after Power Failure

    This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

    Electric Refrigerant Control Valve

    The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.

    R-410A

    A proven blend of refrigerant with a low ozone depleting potential.

    Quiet Mode

    LOW, low fan speed for extra quiet operation.

    SpecificationsExpand All

    • MORE DETAILS
      • Type
      • Unit
      • Indoor Unit
      • Outdoor Unit
      • Performance & Electrical Ratings
      • Capacity Cooling (Btu/h)
      • Capacity Heating (Btu/h)
      • Moisture Removal - High - Pints/H
      • Dry Air Flow - High -CFM
      • Dry Air Flow - Medium -CFM
      • Dry Air Flow - Low -CFM
      • SEER - Cooling
      • EER - Cooling
      • HSPF - Heating
      • Power Supply V, Phase, Hz
      • Running Amps - Cooling - A
      • Running Amps - Heating - A
      • Power Input - Cooling - W
      • Power Input - Heating - W
      • Back-up Heater kW
      • Fuse or Circuit Breaker Capacity - A
      • Features
      • Controls
      • Low Ambient Control
      • Wireless Remote Controller
      • Wired Remote Controller (optional)
      • Fan Speeds
      • Timer
      • Air Deflection - Horizontal
      • Air Deflection - Vertical
      • Air Filter
      • Refrigerant
      • Refrigerant Control
      • Operation Sound - In(Hi / Me / Lo/ Qt) dB-A
      • Operation Sound - Outdoor (Hi) dB-A
      • Refrigerant Piping -Type
      • Refrigerant Piping - Discharge - inches
      • Refrigerant Piping - Suction - inches
      • Refrigerant Pipe Length - ft
      • Elevation Difference - Outdoor Above - ft
      • Elevation Difference - Outdoor Below - ft
      • Dimensions & Weight
      • Height (inches)
      • Width (inches)
      • Depth (inches)
      • Net Weight (lbs.)
    LOAD MORE

    Reviews

    Support

    FAQs
    • What support content is available for my product?

      Click on a link below that interests you the most:

      • Panasonic Community - Join our Community and participate in Discussions where you can learn more about our Products. You will also be able to get advice from other members and Product Experts, as well as documents, FAQ’s, tutorials, and updates.

      • Live Chat - Chat with a representative from 9am-9pm Monday-Friday and 10am-7pm Saturday/Sunday EST.

      • Email Contact - For email inquiries, send them to panasonicwebcasesf@us.panasonic.com, you will receive a response within 24-48 hours.

      • Parts/Accessories - Order parts and/or accessories from our supply chain, Encompass.

      • Service Locator - Locate the closest Authorized repair center to you for TVs, Microwaves, Vacuums, or Massage Chairs.

      • Service Request - If you need a product repaired and is NOT a TV, Microwave, Vacuum, or Massage Chair, you can use our Online Repair Request. There, you will be able to get a repair estimate, pay online, and track the repair status.
    CONTACT INFORMATION
    Consumer Product Support and Technical Assistance
    Operating hours:
    Mon-Fri 9am-9pm EST
    Sat-Sun 10am-7pm EST
    Panasonic USA