Single Split System - Ceiling Recessed Heat Pumps

  • Ceiling Recessed Heat Pumps
  • S-36PU1U6 (Indoor Unit)/U-36PE1U6 (Outdoor Unit)
  • Capacity Cooling: 32,600 (9,500~32,600)/Btu
  • Capacity Heating: 37,600 (8,000~37,600)/Btu


Panasonic’s Ductless Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling for a single. The Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit(condenser) via refrigerant lines & inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.
Microprocessor-Controlled OperationMicroprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
Wireless Remote Control
Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.

Self-Diagnosing Function
Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)

Dry Mode
By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.

3 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.

Air Sweep Control
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.

Louver Control
Louver can be manually set to the desired angle by remote control.

Automatic Heating and Cooling Changeover (Heat Pump)
After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature. (Single Zone Heat Pump unit only)

Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only)

24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.

Weekly Timer

System Controller

Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

Fresh Air Intake (optional)

Branch Extension

Built-In Drain Pump
Max. head 20 inches from the discharge of the indoor unit. Condensate pump is only for allowing drain line to meet minimum gravity flow requirements.

Low Ambient Operation

Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.


SpecificationsExpand All

    • Type Ceiling Recessed
    • Unit Heat Pumps
    • Indoor Unit S-36PU1U6
    • Outdoor Unit U-36PE1U6
    • Grille Assembly CZ-24KPU1U
    • Performance & Electrical Ratings
    • Capacity Cooling (Btu/h) 32,600 (9,500~32,600)
    • Capacity Heating (Btu/h) 37,600 (8,000~37,600)
    • Moisture Removal - High - Pints/H 8.1
    • Dry Air Flow - High -CFM 710
    • Dry Air Flow - Medium -CFM 530
    • Dry Air Flow - Low -CFM 450
    • SEER - Cooling 14.1
    • EER - Cooling 8.5
    • HSPF - Heating 9.6
    • Power Supply V, Phase, Hz 230 / 208 / 1 / 60
    • Running Amps - Cooling - A 15.6 / 17.3
    • Running Amps - Heating - A 14.8 / 16.4
    • Power Input - Cooling - W 2,920 / 2,920
    • Power Input - Heating - W 2,790 / 2,790
    • Back-up Heater kW
    • Fuse or Circuit Breaker Capacity - A "Indoor Unit: 15
    • Outdoor Unit: 30"
    • Features
    • Controls Microprocessor
    • Low Ambient Control Built-in 0¿F
    • Wireless Remote Controller CZ-RWSU2U, CZ-RWSC1U
    • Wired Remote Controller (optional) CZ-RTC2
    • Fan Speeds "3 and Automatic Control /
    • Variable"
    • Timer 7 Days/6 Events
    • Air Deflection - Horizontal -
    • Air Deflection - Vertical Automatic
    • Air Filter Washable
    • Refrigerant R-410A
    • Refrigerant Control Electric Expansion Valve
    • Operation Sound - In(Hi / Me / Lo/ Qt) dB-A
    • Operation Sound - In (Hi/Lo/Q-Lo) dB-A
    • Operation Sound - In (Hi/Me/Lo) dB-A 38 / 35 / 31
    • Operation Sound - Outdoor (Hi) dB-A 49
    • Refridgerant Piping -Type Flare
    • Refridgerant Piping - Discharge - inches 3/8"
    • Refridgerant Piping - Suction - inches 5/8"
    • Refridgerant Pipe Length - ft Max. 165
    • Elevation Difference - Outdoor Above - ft "Max 100
    • * This is maximum elevation difference when the indoor unit is located above the outdoor unit."
    • Elevation Difference - Outdoor Below - ft "Max. 50
    • * This is maximum elevation difference when the indoor unit is located above the outdoor unit."
    • Dimensions & Weight
    • Height (inches) "Indoor Unit: 13-5/16¿
    • Outdoor Unit: 30-23/32¿"
    • Width (inches) "Indoor Unit: 33-55/64¿
    • Outdoor Unit: 37¿"
    • Depth (inches) "Indoor Unit: 33-55/64¿
    • Outdoor Unit: 13-3/8¿"
    • Net Weight (lbs.) "Indoor Unit: 49
    • Outdoor Unit: 128"



Owner's Manuals
  • What support content is available for my product?

    Click on a link below that interests you the most:

    • Panasonic Community - Join our Community and participate in Discussions where you can learn more about our Products. You will also be able to get advice from other members and Product Experts, as well as documents, FAQ’s, tutorials, and updates.

    • Live Chat - Chat with a representative from 9am-9pm Monday-Friday and 10am-7pm Saturday/Sunday EST.

    • Email Contact - For email inquiries, send them to, you will receive a response within 24-48 hours.

    • Parts/Accessories - Order parts and/or accessories from our supply chain, Encompass.

    • Service Locator - Locate the closest Authorized repair center to you for TVs, Microwaves, Vacuums, or Massage Chairs.

    • Service Request - If you need a product repaired and is NOT a TV, Microwave, Vacuum, or Massage Chair, you can use our Online Repair Request. There, you will be able to get a repair estimate, pay online, and track the repair status.
Operating hours:
Mon-Fri 9am-9pm EST
Sat-Sun 10am-7pm EST
Panasonic USA